DRYER DRUM
Fabricated in carbon, stainless or other alloy steel plate with reinforced bands for fitting of tyres and drive rings. Flights or lifters are welded or bolted internally to provide the required degree of contact between the material and the drying air.
The dryer drum is rotated by an electric motor through V-belts, gearbox, pinion and either heavy duty chain to a chainwheel or spur gear drive ring bolted around the dryer drum. For high temperature operation the drive ring is secured to the dryer drum by tangent plates to allow for differential expansion. All drive components are mounted on a common baseplate with guards as required. Integral low speed auxiliary drives can be supplied for emergency or maintenance purposes.
Both ends of the drum may be enclosed by carbon or alloy steel fabricated hoods with air inlet/outlet chutes and suitable seals between the hood and the dryer drum. Where slight ingress of air is acceptable simple labyrinth type seals are used. These comprise of a flexible fabric element, bolted to a stationary endplate and positioned between two steel rings welded to the dryer drum.
Where leakage of air is unacceptable, friction seals are provided, comprising a stationary ring or rings of
semi-rigid compressed fibre or non-ferrous metal loaded onto the machined surface
of the rotating element by springs, pneumatic or hydraulic cylinders. For processes involving
hazardous materials
multiple seals are used with inert gas or vacuum purging of the seal assembly.
AIR HEATER In direct fired systems, the drying air is heated by an oil or gas burner firing into a refractory lined combustion chamber with dilution air being introduced through an annulus between the combustion chamber and air heater outer casing. Burner systems for a range of fuels can be provided. All gas and oil burners are supplied with complete valve trains, spark ignition, modulating control and flame failure control panel. In indirect systems, heat may be transferred to the drying air by means of air to air, steam to air or thermal oil to air heat exchangers or finned tube electric heating elements. For some applications, particularly where the direction of material and air flow are counter-current, the burner may be mounted onto the inlet end hood or endplate to fire directly into the dryer drum. AIR HANDLING SYSTEM. In Rotary Cascade dryers the flow of air through the dryer is induced by a centrifugal fan located at the air outlet end of the dryer. In Rotary Louvre dryers the drying air is provided by a centrifugal fan located up stream of the air heater with filters at the fan inlet, as required. The exhaust air is removed by a second centrifugal fan located at the outlet end of the dryer. All fans are supplied complete with electric motor, V-belt drive and drive guard, all mounted on a common baseframe for ease of installation.
Particles entrained in the exhaust gas stream may be removed by passage of the
gases through high efficiency cyclones, bag filter or wet scrubber or a combination
of same, depending upon the nature and quantity of dust involved. All dust outlets
are fitted with either rotary seals or double flap discharge valves to prevent
excessive ingress of air. Materials of construction for the dust collection equipment
are in line with overall plant requirements.
PROCESS CONTROL
This two step approach generally provides for adequate control of the drying process. When a more sophisticated control system is required it is sometimes possible to control dryer performance from direct measurement of either product or feed moisture content, or both.
In addition, high and low temperature safety interlocks, with or without alarms, may
be provided and output signals from controllers may be fed to continuous chart recorders.
All control instruments together with the necessary motor control gear, relays,
overloads etc. are housed in a control cabinet, prewired for the correct sequential
start-up and safe operation of the plant.